Search
weiter zur Liste zurück pdf print Heavy duty connector C 146 A
![]() | 250 V, 10 A |
![]() | 250 V, 14 A |
![]() | 600 V, 10 A 16 A 20 A |
| In general approvals refer to representative versions of the connector. Extent and specification of tests upon request | |
Connectors C 146 A Male insert No. of contacts 16 + PE, 250 V, Termination: screw, Contact plating: silver plated | ||
| Part No. | C146 10A016 002 4 | |
| Series | Heavy duty connectors C 146 | |
| Subseries | Heavy duty connector C 146 A | |
| Common Characteristics | ||
| No. of contacts | 16 + PE | |
| Weight male insert | 68 g | |
| Weight female insert | 73 g | |
| Electrical Characteristics | ||
| Rated voltage | DIN EN 60664-1 / IEC 60664-1 | 250V |
| Rated impulse voltage | DIN EN 60664-1 / IEC 60664-1 | 4000V |
| Rated current at 40°C | 14 A | |
| Voltage proof | DIN EN 60512-2, Test 4a / IEC 60512-2, Test 4a | 2.800 V |
| Installation category | DIN EN 60664-1 / IEC 60664-1 | III |
| Insulation group | DIN EN 60664-1 / IEC 60664-1 | III b |
| Insulation resistance | DIN EN 60512-2, Test 3a / IEC 60512-2, Test 3a | ≥ 1012 Ω |
| Contact resistance | DIN EN 60512-2, Test 2a / IEC 60512-2 Test 2a | ≤ 5 mΩ |
| Current carrying capacity | DIN EN 60512-3, Test 5b / IEC 60512-2 Test 5b | see derating curves |
| Pollution degree | DIN EN 60664-1 / IEC 60664-1 | 3 |
| Climatical Characteristics | ||
| Climatic category | DIN EN 60068-1 / IEC 60068-1 | 40 / 100 / 21 |
| Upper temperature | + 100 °C / 1000 h | |
| Lower temperatur | - 40 °C / 16 h | |
| Mechanical Characteristics | ||
| IP degree of protection | DIN EN 60529 / IEC 60529 | IP20 mated |
| Mechanical lifetime | IEC 60512-5; Test 9 a | ≥ 500 mating cycles |
| Materials | ||
| Contacts | CuZn | |
| Insert | PBT | |
| Contact plating | silver plated | |
| Further Characteristics | ||
| Termination | screw | |
| Wire gauge | 0,25 - 2,5 mm² | |